• Watch Out for Scammers!

    We've now added a color code for all accounts. Orange accounts are new members, Blue are full members, and Green are Supporters. If you get a message about a sale from an orange account, make sure you pay attention before sending any money!

Search results

  1. A

    Rifle Scopes Zeiss LRP S3 New First Focal Plane Riflescopes for Long-Range Precision Shooting

    I have a 4-25 on a 21lb 338 edge. I have ~220 rounds through it so far. At 100 yards I can't get it as clears as my MRK5. The image doesn't seem that great. Parallax is maxed at 1000yards. While shooting at 1k I did some dialing after shooting about 30 rounds and the turret felt stiff at first...
  2. A

    338 edge & RL26

    Anyone running RL26 in a 338 edge with 300gr OTM?
  3. A

    Issues with case extraction after 3 firing.

    I guess so. I have also heard it called timing? It's a new one for me.
  4. A

    Issues with case extraction after 3 firing.

    Ok update. Problem solved. This is a rem 700 action sn starting in rr. There is a ramp at the top of the bolt lift on the action that mechanically breaks the brass free after fired. It didn't have any of that happening after the action was trued. Tig weld to build up ramp and machine finish...
  5. A

    Issues with case extraction after 3 firing.

    I appreciate all the feedback. I'm taking it for what is. I will try the RP brass if the gunsmith can't fix the issue. Then I will try other options. I will try what I have at my disposal. I'm not discounting the base die option. Definitely frustrating as hell. At 1 point was ready to sell the...
  6. A

    Issues with case extraction after 3 firing.

    N No I haven't. Aren't they for checking sized cases?
  7. A

    Issues with case extraction after 3 firing.

    What do you think I should do? I do have the rifle back at the gunsmith's now. He is going to do a chamber cast to see if he finds anything. If he doesn't I'm having him polish .001" out of the rear of the chamber.
  8. A

    Issues with case extraction after 3 firing.

    Thanks I will check out my sized measurements.
  9. A

    Issues with case extraction after 3 firing.

    Yes I did. I measure base to shoulder and OD at .500 from base. It all got smaller. What do you think I should be measuring for? How much should it size down the OD of the case?
  10. A

    Issues with case extraction after 3 firing.

    I have also tried FL rcbs die with same results.
  11. A

    Issues with case extraction after 3 firing.

    Thanks for all the replies. I do have some RP brass I will try as well. I have tried this with old lot of Norma brass from previous barrel and new brass. Might have to start looking for some ADG.
  12. A

    Issues with case extraction after 3 firing.

    Yes I don't normally bump that far was trying different stuff to try to figure out what the deal was.
  13. A

    Issues with case extraction after 3 firing.

    Yes on both FL each time. And actually bumping shoulder about .007" . The cases chamber just fine after resizing.
  14. A

    Issues with case extraction after 3 firing.

    I have a rem 700 rebarreled. I started with new Norma brass chambered in 300 RUM. I use Forester dies. Been relaoding with this die for several yrs. After it was rebarreled I have a hard time extracting the fired case only after 3 firing. Annealed or not. 1st 2 firing just fine. Chamber fine...
  15. A

    Best Reloading Room Contest

  16. A

    Ordered a prefit in July...still not done....reasonable??

    I ordered a prefit for my rifle in June. Was told 4-8 weeks and still no barrel.
  17. A

    Rifle Scopes 150 Scopes tested, Results Posted !

    Thanks for the info men!
  18. A

    Curtis Axiom/ Helix owners how do you like it?

    I have an Axiom with about 300 rounds through it. It has DLC on bolt. My Tikka is smoother. It is ok. Probably won't buy another. Maybe after I get more rounds through I may change my mind but today "it's ok"